Skip to content

ACEL

ACEL, dir_label, dcval, acval, sigtype, sigpar1, sigpar2;

Defines translational or rotational acceleration loads

  • Acceleration loads are used for inertial effects. Centrifugal forces are ignored.

Input Data⚓︎

Parameter Description
dir_label Available directions (enter a two-character string)
ux or rx
uy or ry
uz or rz
dcval DC-value of the load, used for all types of simulations
→ Real value
del - Delete specified acceleration
acval AC-value of the load, used in harmonic and transient simulations
→ Real value
sigtype Available transient load types (enter a 4-character string)
sine - Sinusoidal function
step - Step function
puls - Periodic pulse function
ramp - Ramp function
→ If empty → Only dcval for transient simulations
sigpar1 sigtype = sine: → sigpar1 - Frequency > 0
sigtype = step: → sigpar1 - Step time ≥ 0
sigtype = puls: → sigpar1 - Period time > 0
sigtype = ramp: → sigpar1 - Ramp time till acval is reached
→ The high-values for all load types are taken from acval
sigpar2 sigtype = sine: → sigpar2 - Phase (default = 0)
sigtype = step or ramp: → sigpar2 unused
sigtype = puls: → sigpar2 → High-pulse time (default = 0.5)